Mechanism of interference by haemolysis in the cardiac troponin T immunoassay

Author:

Sodi Ravinder1,Darn Simon M1,Davison Andrew S1,Stott Anthony1,Shenkin Alan1

Affiliation:

1. Department of Clinical Biochemistry and Metabolic Medicine, Royal Liverpool and Broadgreen University Hospital, Prescot Street, Liverpool, L7 8XP, UK

Abstract

Background: The cardiac troponins have been shown to be sensitive and specific biochemical markers of myocardial infarction and highly prognostic for future adverse events in patients with acute coronary syndromes. There have been reports suggesting that haemolysis causes a negative interference in the cardiac troponin T (cTnT) assay but the mechanism(s) involved remain unknown. Here we show the effects of haemolysis and haemoglobin per se on the cTnT assay. Methods: The effect of haemolysis was studied by the addition of prepared haemolysate to serum samples with known and clinically relevant cTnT levels. The effect of haemoglobin was studied by the addition of haemoglobin of increasing concentrations and noting its effect on the level of cTnT measured. The effect of putative proteases was determined indirectly by incubating samples with spiked cTnT with various protease inhibitors and observing the changes in the measured cTnT levels. Results: The results show that both haemolysis, which is the release of haemoglobin and corpuscular contents, and haemoglobin itself negatively interfere in the cTnT assay in a concentration-dependent manner, although the former had a greater magnitude of effect. On haemolysis, indirect evidence suggests that proteases are released which degrade the cTnT in serum, thus causing the decreased levels detected. Pepstatin A, a reversible inhibitor of aspartic proteinases, effectively inhibited the loss of cTnT in serum at 37°C and pH 7.4 over a 48-h period. We found that at a haemoglobin level of 0.75 g/L, cTnT declined by more than 10% of the initial concentration, suggesting that falsely decreased levels due to haemolysis may significantly affect the clinical utility of the assay. Conclusions: Haemolysis, haemoglobin per se and possibly proteolysis play a role in the negative interference in cTnT assays. Measures to reduce this interference must be implemented.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

Cited by 27 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3