Evaluation of a rapid micro-scale assay for tacrolimus by liquid chromatography-tandem mass spectrometry

Author:

Keevil BG1,McCann SJ2,Cooper DP3,Morris MR3

Affiliation:

1. Department of Clinical Biochemistry, Wythenshawe Hospital, South Manchester University Hospitals NHS Trust, Southmoor Rd, Manchester M23 9LT UK

2. Department of Clinical Biochemistry Wythenshawe Hospital South Manchester University Hospitals NHS Trust Southmoor Rd Manchester M23 9LT UK

3. The Clinical Applications Group Micromass UK Ltd Manchester, UK

Abstract

Background: The immunosuppressive drug tacrolimus has complex and unpredictable pharmacokinetics, therefore regular monitoring is required in patients receiving tacrolimus therapy. We have developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for measuring tacrolimus concentrations in whole blood and have compared it with a microparticle enzyme immunoassay. Methods: For the LC-MS/MS assay, samples were prepared in a 96-deep well microtitre plate by adding 10 µL of blood to 40 µL of 0·1 mol/L zinc sulphate solution. Proteins were precipitated by adding 100 µL acetonitrile containing ascomycin internal standard. After vigorous mixing and centrifugation, 20 µL of the supernatant was injected into the LC-MS/MS system. A C18 cartridge (3 mm × 4 mm) was eluted with a step gradient of 50% to 100% methanol containing 2 mmol/L ammonium acetate and 0·1% (v/v) formic acid, at 0·6 mL/min. The column was maintained at 55°C. Results: The retention times were 0·98 min for ascomycin and 0·98 min for tacrolimus. Cycle time was 2·5 min, injection to injection. The analytes were monitored using a Quattro micro tandem mass spectrometer operated in multiple reaction monitoring mode using the following transitions: m/z821 > 768 (tacrolimus) and m/z809 > 756 (ascomycin). The limit of quantitation was 0·5 µg/L and the assay was linear up to 30 µg/L. Precision of the method, over the concentration range 2·5-15·0 µg/L, was < 7% within-batch and < 6% between-batch. Total time to analyse 24 samples including result generation was 90 min. Conclusion: We conclude that the LC-MS/MS method is quick, precise and robust and will provide a fast turn around of results for the transplant physician.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3