Evaluation of immunoturbidimetric specific protein methods using the Architect ci8200: comparison with immunonephelometry

Author:

Denham Elizabeth1,Mohn Barbara1,Tucker Linda1,Lun Andrea1,Cleave Peter1,Boswell D Ross1

Affiliation:

1. Middlemore Hospital, Auckland, New Zealand

Abstract

Background: Specific proteins have traditionally been analyzed using methodologies such as immunonephelometry on specialized analyzers. It is now possible to perform specific protein testing on clinical chemistry analyzers using immunoturbidimetry. Performance characteristics of turbidimetric assays for eight common specific proteins were evaluated against a nephelometric method. Methods: The Abbott Architect ci8200 and the Beckman Immage were used to perform IgA, IgG, IgM, C3, C4, haptoglobin, and transferrin testing. Abbott, Sentinel and Roche reagents were used to perform CRP testing on the ci8200. The specific protein assays were evaluated for precision, linearity, limit of detection, functional sensitivity, method comparison, prozone, and workflow. Results: Total precision for the immunoturbidimetric assays was consistently better than 2% CV and linear throughout the dynamic range of the assays (recovery ± 10% of target values). The limits of detection, functional sensitivities, and accuracy (as determined by performance against target values for proficiency testing samples and reference materials) are suitable for clinical purposes. Method comparison, as determined by correlation coefficients, and performance against proficiency testing samples, demonstrated good agreement between the turbidimetric and nephelometric tests. Both the turbidimetric and nephelometric assays provided reliable results under conditions of antigen excess. Specific protein test requests could be consolidated within our routine chemistry workload without impacting analytical test throughput. Conclusions: As demonstrated by their performance characteristics, the Architect ci8200 immunoturbidimetric specific protein assays are suitable for routine use and correlate well with representative immunonephelometric assays on the Beckman Immage analyzer. The ability to perform specific protein analyses on an integrated clinical chemistry/immunoassay system can allow for consolidation of testing on a single platform, resulting in improved laboratory operations efficiency.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3