Japanese standard reference material for JDS Lot 2 haemoglobin A1c. I: comparison of Japan Diabetes Society-assigned values to those obtained by the Japanese and USA domestic standardization programmes and by the International Federation of Clinical Chemistry reference laboratories

Author:

Tominaga Makoto1,Makino Hideichi2,Yoshino Gen3,Kuwa Katsuhiko4,Takei Izumi5,Aono Yukuko6,Hoshino Tadao7,Umemoto Masao8,Shimatsu Akira9,Sanke Tokio10,Kuwashima Masamichi11,Taminato Tomohiko12,Ono Junko13

Affiliation:

1. Department of Laboratory Medicine, Yamagata University School of Medicine, 2-2-2 Iida-Nishi, Yamagata 990-9585, Japan and Chairman of the Committee on Standardization of Laboratory Testing Related to Diabetes Mellitus of Japan Diabetes Society

2. Department of Laboratory Medicine, Ehime University School of Medicine, Japan

3. Department of Laboratory Medicine, Toho University School of Medicine, Japan

4. Institute of Clinical Medicine, University of Tsukuba, Japan

5. Department of Laboratory Medicine, Keio University School of Medicine, Japan

6. Clinical Laboratory, Tokyo University Hospital, Japan

7. Institute of Biopathological Medicine, Japan

8. Health Care Technology Foundation Standard Reference Center, Japan

9. Clinical Research Institute, Kyoto National Hospital, Japan

10. Department of Clinical Laboratory Medicine, Wakayama Medical University, Japan

11. Department of Laboratory Medicine, University of Tokushima School of Medicine, Japan

12. Department of Laboratory Medicine, Kagawa University School of Medicine, Japan

13. Department of Laboratory Medicine, Fukuoka University School of Medicine, Japan

Abstract

Background: The Committee on Standardization of Laboratory Testing Related to Diabetes Mellitus of the Japan Diabetes Society (JDS) previously recommended use of the primary calibrator (JDS Lot 1) prepared by the former Committee for Standardization of Glycohemoglobin for standardizing the measurement of haemoglobin A1c (HbA1c). Owing to the depletion of vials of Lot 1 in March 2001, the present committee certified a new reference material, Lot 2, now distributed by the Health Care Technology Foundation (HECTEF). The standardization programme for HbA1c measurement in Japan is currently based on Lot 2, which has values assigned from within Lot 1; the Lot 1 values were consensus values based on assays by laboratories in the Japanese national quality control programme. In this study, for the purpose of international comparison and standardization, Lot 2 was assayed by the JDS reference laboratories, the National Glycoprotein Standardization Program (NGSP) in the USA, and by reference laboratories approved by the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC). Method: The HbA1c values of JDS Lot 2 were transferred from those assigned to Lot 1 using KO500, a high-resolution HPLC method, at three laboratories approved by the JDS committee. Subsequently, vials of JDS Lot 2 were shipped to and assayed by the NGSP in the USA and 10 IFCC reference laboratories. Result: The JDS-assigned HbA1c values (from Lot 1) are 4.04 for Level 1, 5.38 for Level 2, 7.32 for Level 3, 9.88 for Level 4, and 12.63 for Level 5, all expressed as a percentage of total haemoglobin. The values obtained by NGSP and the IFCC laboratories gave the following formulas: NGSP value (%) = JDS value (%) + 0.3%; IFCC value (%) = 1.068 x JDS value (%) -1.741%. Conclusion: Although the values obtained by the IFCC laboratories are significantly lower than the values assigned to Lot 2 by the JDS, the relationship is linear. In addition, standardization of HbA1c based on JDS Lot 2 is currently at a satisfactory level in Japan. As a result, the reassignment of values for Lot 2 to agree with the IFCC values should be relatively easy and will be done after all relevant parties agree to the change.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3