Abstract

Background Renal parenchymal volume (RPV) is considered an important index for clinical decisions. However, normal values have not been established, which hinders the clinical application of RPV. Purpose To test the accuracy and reproducibility of RPV and to investigate the normal values of RPV and kidney length as measured by non-enhanced multidetector computed tomography (CT). Material and Methods An animal model study was performed to test the accuracy and repeatability of RPV measured by CT. RPV of porcine kidneys was measured by water displacement (actual values) and non-enhanced multidetector CT. Individual RPV and kidney length were measured by non-enhanced CT in patients with no clinical history of renal disease ( n = 722). Patient height, age, weight, body surface area (BSA), and body mass index (BMI) were assessed before each patient's CT examination was performed. Results RPV obtained by the CT method was within 2% of the RPV determined by the water displacement method. The normal values of RPV (M ± 1.96 standard deviation [SD]) were 145.72 ± 54.37 mL for men and 132.46 ± 41.94 mL for women. The normal values of kidney length (M ± 1.96 SD) were 10.27 ± 1.98 cm for men and 9.93 ± 1.58 cm for women. RPV did not significantly correlate with BSA or weight in women, but correlated significantly with height and age in both men and women. Of the assessed factors age, weight, height, BSA, and BMI, age, and height were the independent factors that best reflected RPV, in both men and women. Conclusion The present animal study results showed that non-enhanced multidetector CT findings accurately reflect the RPV. The subsequent study performed in humans showed that the RPV of the presently sampled Chinese population was lower than the commonly quoted reference values obtained from Western populations.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3