Accuracy of CT angiography in the assessment of the circle of Willis: comparison of volume-rendered images and digital subtraction angiography

Author:

Han Ari1,Yoon Dae Young1,Chang Suk Ki1,Lim Kyoung Ja12,Cho Byung-Moon3,Shin Yoon Cheol4,Kim Sam Soo2,Kim Keon Ha5

Affiliation:

1. Department of Radiology, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, Seoul

2. Department of Radiology, Kangwon National University College of Medicine, Chuncheon, Kangwon-do

3. Department of Neurosurgery, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, Seoul

4. Department of Thoracic Surgery, Kangdong Seong-Sim Hospital, Hallym University College of Medicine, Seoul

5. Department of Radiology, Samsung Medical Center, Sungkyunkwan University College of Medicine, Seoul, Republic of Korea

Abstract

Background Computed tomography angiography (CTA) is increasingly used for non-invasive imaging of the cerebrovascular diseases. Purpose To evaluate the accuracy of CTA in the assessment of the variation of the segment calibers of the circle of Willis. Material and Methods One hundred and 17 patients with acute SAH (51 men and 66 women, mean age 50.9 years) who underwent CTA using a 16 detector-row CT scanner and DSA were evaluated retrospectively. The CTA and DSA studies were performed within 24 h after the onset of symptoms and within 24 h of each other. A total of 819 arterial segments (A-comA, right and left A1 segment, right and left P-com A, and right and left P1 segment) of the circle of Willis were determined to be aplastic (grade 1), hypoplastic (grade 2), or normal-sized (grade 3) by blinded observers evaluating CTA volume-rendered images. The CTA results were then compared with findings on the corresponding DSA images (reference standard). Results The overall agreement between CTA and DSA was 92.4%. We had 62 (7.6%) cases of disagreement (58 cases of under-estimation and four cases of over-estimation by CTA) between tow modalities. The sensitivity and specificity of CTA in the detection of aplastic and normal-sized segments were more than 90%. In contrast, subgroup analysis of the hypoplastic segments showed a sensitivity of 52.6% and a specificity of 98.2%. Conclusion CTA is highly accurate in the assessment of anatomical variations of the circle of Willis; however, its sensitivity is limited in depicting hypoplastic segments.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 33 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3