Current parathyroid hormone immunoassays do not adequately meet the needs of patients with chronic kidney disease

Author:

Almond Alison1,Ellis Andrew R2,Walker Simon W3

Affiliation:

1. Department of Renal Medicine, Dumfries and Galloway Royal Infirmary, Dumfries DG1 4AP

2. UK National External Quality Assessment Service (UK NEQAS) [Edinburgh]

3. Department of Clinical Biochemistry, Royal Infirmary of Edinburgh, Edinburgh EH16 4SA, UK

Abstract

Background There are significant differences in plasma parathyroid hormone (PTH) results obtained by current immunoassay methods. However, many clinical guidelines relevant to patients with chronic kidney disease (CKD) that recommend PTH target values do not take account of these differences. This raises major questions about the validity of the evidence underpinning current use of PTH measurements in the management of CKD as well as of published relevant audit data. Methods PTH was measured in plasma from patients with CKD in six commercially available immunoassays. The initial pilot study included 19 patients while 98 patients were included in a second extended study. Data from the second study were analysed by regression analysis to obtain assay-specific targets for each immunoassay. Results Although similar PTH reference intervals are provided by most manufacturers, both studies confirmed substantial between-method differences in observed PTH for all patients, with results varying by as much as 4.2-fold between the lowest and highest reading methods. These differences were sufficient to have treatment implications for 79% of the patients in the pilot study. Applying the assay-specific targets derived here to results from the extended study decreased treatment misclassifications from 53% to 12%. Conclusions Existing between-method differences in PTH measurements clearly have treatment implications. International initiatives to address these differences are in progress and will require support and input from all stakeholders. Adoption of assay-specific target values such as those reported here provides a convenient and practical interim solution that should lead to significant improvement in patient management, while also enabling meaningful audit.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

Cited by 48 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3