Elevated phenylalanine on newborn screening: follow-up testing may reveal undiagnosed galactosaemia

Author:

Shakespeare Lynette1,Downing Melanie1,Allen Joyce1,Casbolt Ann-Marie1,Ellin Sheila1,Maloney Martin1,Race Gillian1,Bonham Jim1

Affiliation:

1. Regional Newborn Screening Laboratory, Sheffield Childrens NHS Foundation Trust, Western Bank, Sheffield S10 2TH, UK

Abstract

Introduction Newborn screening for phenylketonuria (PKU) can reveal other conditions which lead to an increased blood spot phenylalanine (Phe) concentration. We have investigated the proportion of blood spot samples that gave a positive screen due to clinically significant conditions other than PKU, compared the positive predictive value (PPV) of our referral Phe cut-off with that recommended by the UK Newborn Screening Programme Centre (UKNSPC) (>210 and >240 μmol/L, respectively) and evaluated the effectiveness of reflex testing for galactosaemia using a lower blood spot Phe cut-off concentration of 130 μmol/L. Methods All blood spot samples that screened positive, for an increased Phe concentration, between April 2001 and March 2008, were identified from the records of the Sheffield Newborn Screening Laboratory and the diagnoses noted. In addition, all cases of galactosaemia detected in or notified to our screening laboratory within this time were also examined and the screened Phe concentrations compared. Results Out of 438,674 babies who were screened, 67 had Phe concentration >210 μmol/L (15 per 100,000). Of these, 40 had PKU or persistent hyperphenylalaninaemia with a Phe concentration identified by screening between 270 and 2350 μmol/L. A further 11 were diagnosed with another clinically significant disorder: galactosaemia ( n = 8), biopterin defects ( n = 2), tyrosinaemia Type 1 ( n = 1). In addition, 16 had transient elevations in Phe. In total, nine cases of galactosaemia were identified, of whom, three had Phe concentrations <240 μmol/L with one asymptomatic individual having a concentration <210 μmol/L. Conclusions Adoption of the UKNSPC recommended cut-off (>240 μmol/L) will not affect the detection rate of classical PKU, but will improve the PPV from 76% to 80%. The use of a lower cut-off (130 μmol/L) for reflex galactosaemia testing enables the timely identification of asymptomatic cases that benefit particularly from early treatment, without prompting any unnecessary clinical referrals or delaying any referrals. This intervention may reduce mortality in this vulnerable group.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3