Fluid collection within the synovial sheath of the tendon of the flexor hallus longus muscle in the tarsal joint of rats: an anatomic variant detectable with magnetic resonance imaging

Author:

Wang Y-X J1,Westwood F R1

Affiliation:

1. AstraZeneca, Alderley Park, Macclesfield, Cheshire, UK

Abstract

Magnetic resonance (MR) images of the right tarsal joint of 22 normal male Han:Wistar rats were acquired using a 4.7 T magnet. An intermediate–high signal area associated with the tendon of the flexor hallus longus muscle was noticed in three rats on T2-weighted images. These areas appeared as an intermediate–high signal on lightly T2-weighted images, but appeared as an iso-signal to muscle structure on proton density weighted images. Histology preparations showed that such areas were caused by a sizable fluid collection within the synovial sheath of the tendon of the flexor hallus longus muscle, with all other joint structures appearing normal. This anatomic variant could be potentially regarded as a lesion on T2-weighted MR images, such as inflamed tissue with oedema, especially when the spatial resolution and/or signal-to-noise ratio are not optimal.

Publisher

SAGE Publications

Subject

General Veterinary,Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3