Telemetric monitoring of fetal blood pressure and heart rate in the freely moving pregnant sheep: a feasibility study

Author:

Abi-Nader Khalil N123,Mehta Vedanta2,Shaw S W Steven24,Bellamy Tom5,Smith Neil5,Millross Laura5,Laverick Beth2,Filippi Elisa12,Boyd Michael5,Peebles Donald M12,David Anna L12

Affiliation:

1. Fetal Medicine Unit, Elizabeth Garrett Anderson Institute for Women's Health, University College London and University College London Hospitals NHS Foundation Trust, London WC1E 6HX, UK

2. Prenatal Cell and Gene Therapy Group, Elizabeth Garrett Anderson Institute for Women's Health, University College London and University College London Hospitals NHS Foundation Trust, London WC1E 6HX, UK

3. Department of Obstetrics and Gynecology, Lebanese American University and UMC Rizk Hospital, Beirut, Lebanon

4. Department of Obstetrics and Gynaecology, Chang Gung Memorial Hospital at Linkou and Chang Gung University, College of Medicine, Taoyuan, 333, Taiwan

5. Biological Services Unit, Royal Veterinary College, London NW1 0TU, UK

Abstract

Remote telemetric monitoring of fetal haemodynamics in pregnant sheep would allow unrestricted animal movement, minimize suffering and distress, and improve animal welfare, while enhancing the quality of data collected. This may also be useful in clinical practice following fetal surgery. Using an open fetal surgical technique at approximately two-thirds of gestation, we implanted the catheter of a D70-PCTP haemodynamic telemetric device (Data Sciences International, Tilburg, The Netherlands) into the carotid artery of the fetal sheep ( n = 4). The attached transmitter was secured to the posterior aspect of the maternal anterior abdominal wall. Two receivers, with a range of 1 m each, were sited in an 11 m2 sheep enclosure to maximize animal freedom while allowing continuous monitoring of the ewe. The receivers were connected by cable to a nearby computer. In the first two procedures, both fetuses died eight and 12 days after surgery, and the catheter tip was observed to be lying in the bicarotid trunk. In the next two procedures the catheter tip was threaded further upstream from the insertion point, in an attempt to reach the fetal aorta, and both fetuses survived until the scheduled postmortem examination at the end of pregnancy. After catheter implantation, fetal blood pressure (BP) and heart rate (HR) were successfully recorded continuously for seven days and then hourly per day for a further three weeks. The fetal BP and HR values were in the normal range for healthy sheep fetuses.

Publisher

SAGE Publications

Subject

General Veterinary,Animal Science and Zoology

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3