Affiliation:
1. *Department of Thoracic Surgery and †Department of Radiology, Marmara University Faculty of Medicine, Istanbul, Turkey
Abstract
Prolonged venous access devices are needed in cancer patients for central venous access. Catheter fragmentation leading to catheter malfunction represents a rare problem. Herein we present our experience in the management of fragmented catheters. Between 2001 and 2003, 183 catheters were placed via the subclavian vein, and five cases of fragmented catheters were observed. Fragments were removed by an Amplatz gooseneck snare (Microvena, St. Paul, MN) with angiographic intervention. The diagnosis of the breakage was made by chest radiography. The incidence of catheter rupture was 2.7%. All fragments were removed by the snare, without any complications. Catheter narrowing and breakage owing to its medial positioning in the subclavian vein were the main causes of catheter malfunction. In any case of catheter malfunction, radiologic evaluation of the catheter must be done to rule out its rupture. Removal of the fragments using the Amplatz snare is a safe and easily applied procedure.
Subject
Cardiology and Cardiovascular Medicine,Radiology Nuclear Medicine and imaging,General Medicine,Surgery
Cited by
16 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献