Laboratory Evaluation of a New Evidential Breath-Alcohol Analyser Designed for Mobile Testing – the Evidenzer

Author:

Fransson M1,Jones A W2,Andersson L3

Affiliation:

1. Research Assistant, Department of Forensic Toxicology, University Hospital, 581 85 Linköping, Sweden

2. Professor, Department of Forensic Toxicology, University Hospital, 581 85 Linköping, Sweden

3. Forensic Scientist, National Laboratory of Forensic Science, 581 94 Linköping, Sweden

Abstract

The Evidenzer is a new kind of forensic breath-alcohol analyser, designed for use both at a police station (stationary) and also in a police vehicle (mobile) at the roadside. In this paper we report the accuracy and precision of the Evidenzer, determined under controlled laboratory conditions. The results were compared with a well-established breath-alcohol instrument (Intoxilyzer 5000S) and also with the concentration of alcohol in venous blood. Twenty healthy volunteers (10 men and 10 women) consumed ethanol (0.4 g/kg) in 15 minutes starting two to three hours after their last meal. Venous blood and breath were obtained for determination of ethanol at 15-30 minute intervals for up to four hours post-dosing. There was a good overall agreement between the two breath-alcohol instruments and the mean bias was only 0.003 mg/L (95% limits of agreement of -0.016 to 0.023 mg/L). The standard deviation (SD) of measuring ethanol in breath was about the same for both instruments, being 0.006 mg/L, and this corresponds to a relative precision or coefficient of variation (CV) of 4.7%. When the Evidenzer was used to analyse ethanol vapour (0.50 mg/L) generated from a wet-bath simulator, i.e. in-vitro conditions, the coefficient of variation was 0.7% indicating high analytical precision. The concentration of ethanol in venous blood and breath were highly correlated (r=0.95) although systematic differences existed depending on time after drinking when comparisons were made. Both breath-alcohol instruments gave results higher than venous blood alcohol in tests made at 15 minutes after the end of drinking whereas at all later times the venous blood-alcohol concentration was higher than the breath instrument readings. These observations can be explained by the time necessary for ethanol to equilibrate between arterial blood and tissue water and by the resulting arterial-venous differences. The time-course of alcohol concentration in arterial blood runs closer to the breath-alcohol concentration rather than the venous blood draining the forearm muscle tissue. The new Evidenzer instrument was easy to operate and gave accurate and precise results compared with Intoxilyzer 5000S.

Publisher

SAGE Publications

Subject

Law,Health Policy,Issues, ethics and legal aspects

Cited by 18 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3