Use of a common standard improves the performance of liquid chromatography-tandem mass spectrometry methods for serum 25-hydroxyvitamin-D

Author:

Carter Graham D1,Jones Julia C1

Affiliation:

1. Clinical Chemistry Department, Imperial College Healthcare NHS Trust, Charing Cross Hospital, London W6 8RF, UK

Abstract

Background Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is becoming increasingly popular for measuring 25-hydroxyvitamin-D (25-OH-D). Results submitted to the International Quality Assessment Scheme (DEQAS) have shown poor interlaboratory agreement. We investigated whether the use of a common standard would reduce interlaboratory imprecision. Methods A commercial standard and two controls were distributed with the DEQAS samples in January 2008. Participants were asked to calculate the results of samples and controls using their usual standard and the commercial standard. A method questionnaire was also distributed. Results Use of a common standard reduced the mean interlaboratory imprecision (coefficient of variation [CV]) for total 25-OH-D from 16.4% (in-house standards) to 10.4% (common standard). For 25-OH-D3 and 25-OH-D2, the mean CVs were reduced from 16.7% and 21.1% to 8.5% and 12.6%, respectively. Mean values obtained for total 25-OH-D using the common standard were higher by 6.1%. Conclusions Use of a common standard improved agreement among laboratories using LC-MS/MS methods for 25-OH-D. This suggests that problems with assay standardization contribute to interlaboratory imprecision. This may be related to the nature of the matrix used for working standards or errors in the calibration of stock standard solutions of 25-OH-D. Some participants used a gravimetric method, others UV spectrophotometry, to establish the concentration of stock solutions. Among the latter group there was uncertainty over the molar absorption coefficient of 25-OH-D solutions. We conclude that LC-MS/MS is not yet sufficiently robust to become the reference method for 25-OH-D and that gas chromatography-mass spectrometry might be a more suitable candidate.

Publisher

SAGE Publications

Subject

Clinical Biochemistry,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3