Affiliation:
1. Medicinal Safety Laboratories, Yamanouchi Pharmaceutical Co. Ltd, Itabashi-ku, Tokyo, Japan
Abstract
We examined the effects of handling, cage transportation, anaesthesia and repeated bleeding on plasma glucose levels in mice and rats. Plasma glucose was determined using a compact glucose analyser Antsense®, which provides a quick and accurate method without the necessity for special specimen preparation. In mice, plasma glucose was significantly elevated after primary handling or cage transportation. Anaesthesia increased plasma glucose levels two-fold, whilst repeated bleeding induced a rapid but transient increase. However, it was found to be possible to sample plasma glucose levels at one-hour intervals without any apparent effect on plasma glucose level as a result of stress from the sampling procedure. In contrast, the same set of procedures i.e. handling, cage transportation and anaesthesia, when performed on rats, seemed to have small or no observable effect on levels of plasma glucose. These results show the importance of the sampling procedure when determining plasma glucose in mice. It is recommended that the procedure which causes the least influence on endogenous glucose levels should be the method of choice and that animals should be acclimatized to the procedure, by appropriate handling, prior to sampling.