Three-dimensional double-echo steady-state (3D-DESS) magnetic resonance imaging of the knee: establishment of flip angles for evaluation of cartilage at 1.5 T and 3.0 T

Author:

Moriya Susumu12,Miki Yukio3,Matsuno Yukako4,Okada Masayo5

Affiliation:

1. Ishikawa Clinic, Kyoto

2. Division of Health Sciences, Graduate School of Medical Science, Kanazawa University, Kanazawa

3. Department of Radiology, Osaka City University Graduate School of Medicine, Osaka

4. Oike Clinic, Kyoto

5. Shijyo-karasuma Clinic, Kyoto, Japan

Abstract

Background The effect of flip angle (FA) on synovial fluid and cartilage signal and on image contrast using three-dimensional double-echo steady-state (3D-DESS) sequence have only been performed with 1.0-T but not with 1.5-T or 3.0-T scanners. Purpose To identify the FA that gives the maximum synovial fluid and cartilage values, and to identify the FA at which maximum values of synovial fluid-cartilage contrast-to-noise ratio (CNR) in 3D-DESS sequences when 1.5-T and 3.0-T scanners are used. Material and Methods Using 3D-DESS with water-excitation pulse, mid-sagittal plane images of the knees of 10 healthy volunteers (5 men, 5 women; age range, 21–42 years) were obtained with FA varying from 10° to 90°. Synovial fluid signals, cartilage signals, and background were measured at each FA, and the FA that gave the highest synovial fluid and cartilage values was obtained. Synovial fluid-cartilage CNR was also calculated, and the FA that gave the largest CNR was obtained. Results At 1.5 T, the maximum synovial fluid signal was at FA 90°, and the maximum cartilage signal was at FA 30°. Synovial fluid-cartilage CNR was highest at FA 90° ( P < 0.05). At 3.0 T, the maximum synovial fluid signal was at FA 90°, and the maximum cartilage signal was at FA 20°. Synovial fluid-cartilage CNR was highest at FA 90° ( P < 0.05). Conclusion In order to improve the visibility of cartilage itself, FA settings of 30° at 1.5 T and 20° at 3.0 T are apparently ideal. For observing the cartilage surface, the most effective FA setting is 90° for both 1.5 T and 3.0 T.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3