Evaluation of middle cerebral artery stents using multidetector row CT angiography in vivo study: comparison of the three different kernels

Author:

Jang Jin Hee1,Lim Yeon Soo1,Lee Youn Joo1,Yoo Won Jong1,Sung Mi Sook1,Kim Bum Soo2

Affiliation:

1. Department of Radiology, Bucheon St Mary's Hospital, College of Medicine, The Catholic University of Korea, Bucheon

2. Department of Radiology, Seoul St Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea

Abstract

Background There are very few reports assessing middle cerebral artery (MCA) stents using multidetector computed tomography (MDCT). Purpose To assess MCA stents using multidetector CT angiography (CTA) in vivo evaluation: the differences in the CTA results according to the three different kernels. Material and Methods We retrospectively evaluated 27 MCA stents from 26 patients who underwent CTA with 16- and 64-slice MDCT after percutaneous transluminal angioplasty and stenting (PTAS). By CTA, using medium-smooth kernel (B30), medium-sharp kernel (B50), and sharp kernel (B60), the lumen diameter, artificial luminal narrowing (ALN), and subjective visibility score of the stented vessels were evaluated. The subjective visibility score ranged from 1 (poor quality) to 5 (excellent) using a five-point scale. Results There were excellent inter-observer agreements for the lumen diameter measurements ( P < 0.001). The mean diameter of the stented vessels was 2.10 ± 0.31 mm on digital subtraction angiography (DSA), 0.93 ± 0.20 mm on CTA using B30, 1.18 ± 0.27 mm on CTA using B50, and 1.29 ± 0.29 mm on CTA using B60. The mean ALN was 55.7 ± 6.0% on CTA using B30, 43.8 ±7.5% on CTA using B50, and 38.7 ± 8.3% on CTA using B60. CTA with higher kernels had a smaller ALN than images with smaller kernels. The median subjective visibility score on the CTA using B50 was 3, which was higher than for the other kernels. The differences in the lumen diameter, ALN, and the subjective visibility score of the stented vessels on CTA using the three different kernels was statistically significant ( P < 0.001). Conclusion The sharp kernel was better to assess the lumen diameter and ALN, but was inferior to the medium-sharp kernel for in-stent evaluation due to high image-to-noise. CTA with medium-sharp kernel showed good lumen visibility and acceptable ALN for MCA stents. This could therefore be a non-invasive, readily applicable clinical method for assessing MCA stent patency after stent placement.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3