Magnetic measurements of peripheral nerve function using a neuromagnetic current probe

Author:

Wijesinghe Ranjith S1

Affiliation:

1. Department of Physics and Astronomy, Ball State University, Muncie, IN 47306, USA

Abstract

The progress made during the last three decades in mathematical modeling and technology development for the recording of magnetic fields associated with cellular current flow in biological tissues has provided a means of examining action currents more accurately than that of using traditional electrical recordings. It is well known to the biomedical research community that the room-temperature miniature toroidal pickup coil called the neuromagnetic current probe can be employed to measure biologically generated magnetic fields in nerve and muscle fibers. In contrast to the magnetic resonance imaging technique, which relies on the interaction between an externally applied magnetic field and the magnetic properties of individual atomic nuclei, this device, along with its room-temperature, low-noise amplifier, can detect currents in the nano-Ampere range. The recorded magnetic signals using neuromagnetic current probes are relatively insensitive to muscle movement since these probes are not directly connected to the tissue, and distortions of the recorded data due to changes in the electrochemical interface between the probes and the tissue are minimal. Contrary to the methods used in electric recordings, these probes can be employed to measure action currents of tissues while they are lying in their own natural settings or in saline baths, thereby reducing the risk associated with elevating and drying the tissue in the air during experiments. This review primarily describes the investigations performed on peripheral nerves using the neuromagnetic current probe. Since there are relatively few publications on these topics, a comprehensive review of the field is given. First, magnetic field measurements of isolated nerve axons and muscle fibers are described. One of the important applications of the neuromagnetic current probe to the intraoperative assessment of damaged and reconstructed nerve bundles is summarized. The magnetic signals of crushed nerve axons and the determination of the conduction velocity distribution of nerve bundles are also reviewed. Finally, the capabilities and limitations of the probe and the magnetic recordings are discussed.

Publisher

SAGE Publications

Subject

General Biochemistry, Genetics and Molecular Biology

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3