Development of the shunt implantation technology in patients with open-angle glaucoma and clinical results

Author:

Smetankin I. G.1ORCID,Salahutdinov I. M.1ORCID,Bessonova L. A.1ORCID,Belousova N. U.1ORCID

Affiliation:

1. Privolzhsky Research Medical University

Abstract

Glaucoma continues to lead among the irreversible causes of blindness and low vision. In some cases, surgical treatment is the method of choice even for newly detected glaucoma. The indication for the use of drains is refractory glaucoma, but today microshunting is widely enough used in patients with primary open angle glaucoma at the first stage of surgical treatment.The aim of the study is to develop a technology of polymeric microshunt implantation and estimate the clinical effect of its using for the surgical treatment of worsening and terminal open‑angle glaucoma.Materials and Methods. 30 patients (30 eyes) with open‑angle glaucoma and high level of intraocular pressure (IOP) were observed. All the patients were given modified partial‑thickness deep sclerectomy with the polymeric microshunt implantation by means of the developed insertor. The shunt made of polymer (polycarbonate methacrylate) is a hollow square tube 2.5 mm long, the diameter of the inner hole is 0.2 mm. The needle cut angle is 45 degrees, the end of the needle has an additional lateral anti‑lock hole. The microshunt consists of two parts: the needle for placing into the anterior chamber and supporting elements for the shunt fixation between the superficial and deep layers of the sclera. The insertor we created is an instrument 12.2 mm long with the 2.2 mm long thin rod at the end. Before implantation the shunt put on the needle is securely fixed due to the working part of the tool cut (45 degrees), which is congruent to the external part of the shunt. After the implantation the needle is removed from the shunt by pressing the side button of the insertor that allows to leave the shunt at the implantation site.Results. All the patients demonstrated good results at a distant time with areactive current of postoperative period. Computer static projector perimetry and visometry didn’t reveal any negative dynamics during the entire observation period. According to ophthalmoscopy and optical coherent tomography results, the changes of the optic disc, ganglion cells layer in the macula and peripapillary nerve fibers remained at the same level.Conclusion. Antiglaucomatous surgery according to the invented technology of the polymeric shunt implantation with the help of the original insertor in combination with modified sclerectomy provides stable hypotensive effect and minimizes complications. In addition, the method helps to stabilize visual functions in patients with worsening and terminal open‑angle glaucoma and high level of IOP.

Publisher

Academy of Medical Optics and Optometry

Subject

General Medicine

Reference8 articles.

1. Neroev V.V., Bykov V.P., Kvasha O.I., Belevtseva T.A. Artificial vision: advances, topical issues, and prospects. Russian ophthalmological journal. 2018;11(3)(supplement):3–27. https://doi.org/10.21516/2072-0076-2018-11-3-supplement-3–27. (In Russ.)

2. National guide to glaucoma / ed. by Egorov E.A., Astahov U.S., Erichev V.P. Moscow, 2015. 456 p. (In Russ.)

3. Patel S., Pasquale L.R. Glaucoma drainage devices: a review of the past, present, and future. Semin Ophthalmol. 2010 Sep–Nov;25(5–6):265–270. https://doi.org/10.3109/08820538.2010.518840

4. Gedde S.J., Panarelli J.F., Banitt M.R., Lee R.K. Evidenced-based comparison of aqueous shunts. Curr Opin Ophthalmol. 2013 Mar;24(2):87–95. https://doi.org/10.1097/ICU.0b013e32835cf0f5

5. Erichev V.P., Asratyan G.K. The efficacy and safety of microshunt use in primary glaucoma surgery. Glaucoma. 2012;4:50–54. (In Russ.)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3