Transvascular and intravascular fluid transport in the rainbow trout:revisiting Starling's forces, the secondary circulation and interstitial compliance

Author:

Olson Kenneth R.1,Kinney Daniel W.1,Dombkowski Ryan A.1,Duff Douglas W.1

Affiliation:

1. Indiana University School of Medicine, South Bend Center for Medical Education, University of Notre Dame, Notre Dame IN 46556, USA

Abstract

SUMMARYThe kinetics of transvascular fluid transport across fish capillaries and redistribution of fluids between intravascular compartments in intact fish are unknown. Cannulae were placed in the dorsal aorta (DA) and caudal vein (CV) of rainbow trout Oncorhynchus mykiss (mass 0.45-0.85 kg) and the fish spleenectomized. The following day a peristaltic pump was fitted to complete the extracorporeal arterio-venous circulation. Hematocrit (Hct) was monitored in unanesthetized fish either manually, by collecting blood from the extracorporeal loop at 5 min intervals for a period of 1 h (groups 1 and 2),or continuously (instantaneously) with an impedance flow-cell inserted in the aortic cannula (group 3). Fish in group 1 were volume expanded by injecting a volume of saline (0.9 g% NaCl; SI) or trout plasma (PI) equivalent to 40% of the plasma volume. In group 2, 20% or 35% of the blood volume was removed, and in group 3, 35% of the blood volume was removed. Plasma volume (Vp)was calculated from an assumed blood volume of 35 ml kg-1 and the Hct. Vp declined mono-exponentially after SI with a half-time of 6.8 min and Vp reached a new steady state at 28.1 ml kg-1; 30%of the injected volume remained in the vasculature. Volume recovery after PI was also mono-exponential, but slower (half-time=15.4 min) than SI, whereas the steady-state Vp (27.3 ml kg-1) was similar and 30% of the injected volume remained in the vasculature. Thus the presence of plasma proteins delayed fluid efflux from the vasculature, but did not affect the volume lost. Transvascular fluid filtration coefficients calculated from this data were 5.5 (SI) and 4.5 ml mmHg-1 kg-1min-1 (PI), and interstitial compliance was 11.8 (SI) and 9.7 ml mmHg-1 kg-1 (PI). The rate of volume recovery after 20%or 35% hemorrhage was independent of the hemorrhage volume (half-time=13.3 and 15.1 min, respectively) and similar to the half-time of PI, indicating that protein-rich interstitial fluid is returned to the vasculature. There is a nearly instantaneous change in Hct that occurs during the hemorrhage period;it is dependent on hemorrhage duration and volume and not associated with the subsequent mono-exponential recovery. This initial response is best explained by a rapid fluid shift from a large-volume (approximately 40% of total blood volume), low-hematocrit (less than half of systemic Hct) microcirculation into the higher-hematocrit macrocirculation. These studies are consistent with transcapillary fluid flux across a barrier that is highly permeable to protein, and cannot be explained by fluid shift between primary and secondary circulations, or by transcapilllary flux across a capillary bed that is impermeable to plasma proteins. The results support the hypothesis that whole-body reflection coefficients in trout are very low and that plasma oncotic pressure is not a determinant of transcapillary fluid balance. They also show that both transvascular and intravascular fluid movements are important effectors of central volume homeostasis.

Publisher

The Company of Biologists

Subject

Insect Science,Molecular Biology,Animal Science and Zoology,Aquatic Science,Physiology,Ecology, Evolution, Behavior and Systematics

Reference39 articles.

Cited by 41 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司