A Prototype MR Compatible Positioning Device for Guiding a Focused Ultrasound System for the Treatment of Abdominal and Thyroid Cancer

Author:

Mylonas Nicos1,Damianou Christakis2

Affiliation:

1. Frederick University Cyprus, Limassol, Cyprus & City University, London, UK

2. Cyprus University of Technology, Limassol, Cyprus

Abstract

A prototype magnetic resonance imaging (MRI)-compatible positioning device that navigates a high intensity focused ultrasound (HIFU) transducer is presented. The intended application is to treat eventually tumours in the abdominal and thyroid. The positioning device has 3 user-controlled stages that allow access to various targets using a top to bottom coupling approach. Materials and Methods. The positioning device incorporates only MRI compatible materials such as piezoelectric motors, ABS plastic, brass screws, and brass rack and pinion. Results The MRI compatibility and the accuracy of the system were successfully demonstrated in an open MRI scanner. The robot has the ability to accurately move the transducer thus creating discrete and overlapping lesions in rabbit liver in vivo. This simple, cost effective positioning device can be placed mostly on the structure of an open MRI gantry. Due to the size of this positioning device, the proposed prototype in its current form cannot be used in any closed MRI system. The novelty of this positioning device is the MRI compatible design and its intended application which is the treatment of tumors in the abdominal area using focused ultrasound. This system can be utilized in the future to treat patients with cancer in the liver, kidney, pancreas and thyroid provided that the accuracy of the positioning device is greatly improved.

Publisher

IGI Global

Reference42 articles.

1. High-intensity focused ultrasound in the treatment of prostatic tissue

2. In vivo effects of high-intensity ultrasound on prostatic adenocarcinoma, Dunning R3327.;J. Y.Chapelon;Cancer Research,1992

3. Towards MRI guided surgical manipulator.;K.Chinzei;Medical Science Monitor,2001

4. MR-Guided Focused Ultrasound Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Robotic interventions;Handbook of Medical Image Computing and Computer Assisted Intervention;2020

2. An MRI-conditional motion phantom for the evaluation of high-intensity focused ultrasound protocols;The International Journal of Medical Robotics and Computer Assisted Surgery;2015-09-29