Affiliation:
1. University of Salento, Italy
Abstract
This chapter focuses on the Diffusion Absorption Refrigerator (DAR) cycle and describes a new advanced thermodynamic model which allows good predictions of the chiller performance in terms of efficiency and cooling capacity, starting from a precise evaluation of the thermo-physical properties of the working mixture at each point of the circuit. A steady state thermodynamic analytical model of the thermal pump driving the DAR is also included. In addition, the experimental validation of the model, performed on a prototype built coupling a domestic 750 W-magnetron with a small purposely modified commercial DAR to activate the thermal pump, is here included: a maximum mismatch of 2.32% in the weak mixture mass flow rate and lower than 5% in COP between the predicted and measured data were found.
Reference43 articles.
1. Theoretical Investigation and Parameter Study of a Diffusion Absorption Refrigeration System.;T.Al-Shemmeri;Proceedings of the 21st IIR International Congress of Refrigeration,2003
2. Effects of tube diameter and submergence ratio on bubble pattern and performance of air-lift pump
3. A simple two-phase frictional pressure drop calculation method
4. Couplage de machine à absorption-diffusion et de capteur solaire
5. Carluccio, F., Starace, G., & Bongs, C. (2014). Modeling and Simulation of Gas Absorption Heat Pump. In Proceedings of the International Sorption Heat Pump Conference (ID 106). Washington D.C.: Publisher.