Synchrophasor-Based Wide Area Protection Scheme for System Stressed Conditions to Avoid Power System Blackout

Author:

Venkatanagaraju Kasimala1,Biswal Monalisa1

Affiliation:

1. National Institute of Technology Raipur, India

Abstract

Protection of transmission system is crucial for the secured and stable operation of power system. Under stress conditions, the operating parameters of power system violate their limits. From the past anatomy reports of several blackouts, it is clear that equipment, control, and protective relay failures are the major causes behind large power system failure. From study, it is also revealed that failure of back-up protection is more prone during system stressed conditions. In transmission system, third-zone of distance relay is highly affected by system stressed events such as voltage instability and load encroachment. As third-zone protection is a delayed protection scheme, with the help of wide area measurement system better protection function can be provided to reduce future percentage of blackout. In this chapter, a detailed discussion about the existing solutions is provided to mitigate the issue of system stressed conditions and a synchrophasor technology-based approach is provided. Results for different cases are provided to show the efficacy of the proposed method.

Publisher

IGI Global

Reference55 articles.

1. AER. (2007). Final the events of 16 January 2007 investigation report. Retrieved from https://www.aer.gov.au

2. Challenges and Opportunities of Load Frequency Control in Conventional, Modern and Future Smart Power Systems: A Comprehensive Review

3. Fault detection and isolation in power systems using unknown input observer;H. H.Alhelou;Advanced Condition Monitoring and Fault Diagnosis of Electric Machines,2018

4. Alhelou, H. H., Golshan, M., & Fini, M. (2018). Wind Driven Optimization Algorithm Application to Load Frequency Control in Interconnected Power Systems Considering GRC and GDB Nonlinearities. Electric Power conponents and Syst.

5. Hierarchical plug-in EV control based on primary frequency response in interconnected smart grid

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Mitigation of Power System Blackout with Microgrid System;Lecture Notes in Electrical Engineering;2020