Imaging Advances of the Cardiopulmonary System

Author:

Llobet Holly1,Llobet Paul1,LaBrunda Michelle1

Affiliation:

1. Cabrini Medical Center, USA

Abstract

A technological explosion has been revolutionizing imaging technology of the heart and lungs over the last decade. These advances have been transforming the health care industry, both preventative and acute care medicine. Ultrasound, nuclear medicine, computed tomography (CT), and magnetic resonance imaging (MRI) are examples of radiological techniques which have allowed for more accurate diagnosis and staging (determination of severity of disease). The most notable advances have occurred in CT and MRI. Most medical subspecialties rely on CT and MRI as the dominant diagnostic tools an exception being cardiology. CT and MRI are able to provide a detailed image of any organ or tissue in the body without the necessity of invasive or painful procedures. Virtually any individual could be tested as long as they are able to remain immobile for the duration of the study. Image generation traditionally has been limited by the perpetual motion of the human body. For example, the human heart is continually contracting and relaxing without a stationary moment during which an image could be obtained. Lung imaging has been more successful than cardiac imaging, but studies were limited to the length of time an ill person is able to hold his or her breath. Historically, imaging technology was limited by inability to take a picture fast enough of a moving object while maintaining a clinically useful level of resolution. Recent technologic innovation, resulting in high speed electrocardiogram- gated CT and MRI imaging, now allows the use of these imaging modalities for evaluation of the heart and lungs. These novel innovations provide clinicians with new tools for diagnosis and treatment of disease, but there are still unresolved issues, most notably radiation exposure. Ultrasound and MRI studies are the safest of the imaging modalities and subjects receive no radiation exposure. Nuclear studies give an approximate radiation dose of 10mSv and as high as 27mSv (Conti, 2005). In CT imaging, radiation dose can vary depending on the organ system being imaged and the type of scanner being used. The average radiation dose for pulmonary studies is 4.2mSv (Conti, 2005). The use of multi-detector CT (MDCT) to evaluate the heart can range from 6.7—13mSv. To put it into perspective, according to the National Institute of Health, an average individual will receive a radiation dose of 360mSv per year from the ambient environment. It is unlikely that the radiation doses received in routine imaging techniques will lead to adverse reactions such as cancer, but patients should be informed of the risks and benefits of each procedure so that they can make informed decisions. It is especially important that patients be informed when radioactive material is to be injected into their bodies. The reasons for this will be discussed later on in the chapter.

Publisher

IGI Global

Reference15 articles.

1. Bedside echocardiography in the assessment of the critically ill

2. Coronary computed tomography angiography: Overview of technical aspects, current concepts, and perspectives.;C.Chartrand-Lefebvre;Canadian Association of Radiologists Journal,2007

3. One-stop cardiovascular diagnostic imaging (and radiation dose)

4. Will 3-dimensional PET-CT enable the routine quantification of myocardial blood flow?

5. Clinical Myocardial Perfusion PET/CT

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3