Optimization of Radiation Exposure when Examining Patients with Pathology of the Craniovertebral Region

Author:

Gukova A. D.1ORCID,Petrovskaya V. V.2ORCID,Lubashev Ya. A.1

Affiliation:

1. Department of ICDC of PAO «Gazprom»

2. Federal State Budgetary Education Institution of Higher Education «Russian University of Medicine», Ministry of Healthcare of Russia

Abstract

The diagnostics are based on the principle of obtaining informative and high-quality images with minimal radiation exposure using radiation diagnostic methods: traditional radiography, multislice and cone-beam computed tomography.When conducting X-ray examinations, the main factors in reducing the risk of radiation exposure are the use of highly sensitive digital diagnostic image receivers, minimal exposure time, and a minimum number of images per examination. A lower current value and high anode voltage values, a minimum focal spot size, the placement of the tube as far as possible from the patient and the image receiver as close to the patient as possible, collimation of the radiation beam, and preference for a low radiation dose rate mode are also factors in reducing the risk of radiation exposure.Imaging of the craniovertebral region using cone beam computed tomography offers the opportunity to evaluate the bone structure of the region in detail, with an equal or less effective dose to the patient.

Publisher

Central Research Institute of Radiation Diagnostics

Reference16 articles.

1. Guzino P. V., Pesty’uk E. L. On the Рroblem of Reducing Radiation Exposure to Patients with Medical Exposure and Ways to Solve it. Aktual’nyye voprosy radiatsionnoy i ekologicheskoy meditsiny, luchevoy diagnostiki i luchevoy terapii. Grodno, 2022. P. 101–104. (In Russ.). http://www.grsmu.by/files/file/science/konferencija/sbornik/sbornik_rad_med_2022.pdf#page=101

2. Kalinina M. V., Zhukova Zh. V. Methodological Aspects of Substantiation of Control Diagnostic Levels of Patient Exposure During Medical X-ray Diag nos tic Studies. Radiatsionnaya gigiyena. 2020. 13(3):123-130. (In Russ). https://doi.org/10.21514/1998-426X-2020-13-3-123-130

3. Krasnov A. S., Kabanov D. O., Tereschenko G. V. Dosimetry Basics and Dose Optimization Strategies for CT Examinations. Pediatric Hematol., Oncol. and Immunopathol. 2018;17(3):127-132. (In Russ.). https://doi.org/10.24287/1726-1708-2018-17-3-127-132

4. Control of Effective Radiation Doses to Patients During Medical X-ray Examinations: Guidelines 2.6.1.2944-11. Federal’nyy tsentr gigiyeny i epide mio logii Rospotrebnadzora, 2011. 38 p. (In Russ.).

5. Determination of the Radiation Output of X-ray Emitters of Medical X-ray Diagnostic Devices. Metodicheskiye reko men datsii 0100/12883-07:34. M.: Minzdrav Rossii, 2007. (In Russ).

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3