Affiliation:
1. Central Institute for the Deaf, St. Louis, Missouri
Abstract
The accuracy of spectrographic techniques and of linear prediction analysis in measuring formant frequencies is compared. The first three formant frequencies 90 synthetic speech tokens were measured by three experienced spectrographic readers and by linear prediction analysis. For fundamental frequencies between 100 and 300 Hz, both methods are accurate to within approximatey , ±60 Hz for both first and second formants. The third formant can be measured with the same degree of accuracy by linear prediction, but only to within ± 110 by spectrographic means. The accuracy of both methods decreases greatly when fundamental frequency is 350 Hz or greater. These limits of measurement appear to be within the range of the difference limens for formant frequencies
Publisher
American Speech Language Hearing Association
Subject
Speech and Hearing,Linguistics and Language,Language and Linguistics
Cited by
71 articles.
订阅此论文施引文献