The Effects of Noise and Simulated Conductive Hearing Loss on Physiological Response Measures During Interactive Conversations

Author:

Aliakbaryhosseinabadi Susan12ORCID,Keidser Gitte13,May Tobias2,Dau Torsten2ORCID,Wendt Dorothea12,Rotger-Griful Sergi1ORCID

Affiliation:

1. Eriksholm Research Centre, Oticon A/S, Snekkersten, Denmark

2. Hearing System Section, Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark

3. Department of Behavioral Sciences and Learning, Linnaeus Center HEAD, Linköping University, Sweden

Abstract

Purpose: The purpose of this work was to study the effects of background noise and hearing attenuation associated with earplugs on three physiological measures, assumed to be markers of effort investment and arousal, during interactive communication. Method: Twelve pairs of older people (average age of 63.2 years) with age-adjusted normal hearing took part in a face-to-face communication to solve a Diapix task. Communication was held in different levels of babble noise (0, 60, and 70 dBA) and with two levels of hearing attenuation (0 and 25 dB) in quiet. The physiological measures obtained included pupil size, heart rate variability, and skin conductance. In addition, subjective ratings of perceived communication success, frustration, and effort were obtained. Results: Ratings of perceived success, frustration, and effort confirmed that communication was more difficult in noise and with approximately 25-dB hearing attenuation and suggested that the implemented levels of noise and hearing attenuation resulted in comparable communication difficulties. Background noise at 70 dBA and hearing attenuation both led to an initial increase in pupil size (associated with effort), but only the effect of the background noise was sustained throughout the conversation. The 25-dB hearing attenuation led to a significant decrease of the high-frequency power of heart rate variability and a significant increase of skin conductance level, measured as the average z value of the electrodermal activity amplitude. Conclusion: This study demonstrated that several physiological measures appear to be viable indicators of changing communication conditions, with pupillometry and cardiovascular as well as electrodermal measures potentially being markers of communication difficulty.

Publisher

American Speech Language Hearing Association

Subject

Speech and Hearing,Linguistics and Language,Language and Linguistics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3