Multifrequency Narrowband Chirp Evoked Cervical Vestibular Myogenic Potentials: Evaluation of Responses in Normal-Hearing Young Adults

Author:

Lodha Vidhi1ORCID,Neupane Anuj Kumar1ORCID

Affiliation:

1. School of Audiology & Speech-Language Pathology, Bharati Vidyapeeth (Deemed to be University), Pune, India

Abstract

Purpose: The study aimed to explore the various parameters of multifrequency narrowband Claus Elberling chirp (NB CE-chirp) evoked cervical vestibular evoked myogenic potentials (cVEMPs) in normal-hearing healthy young adults. The study also attempted to define the optimal frequency tuning characteristic of NB CE-chirp evoked cVEMPs. Method: cVEMP was performed on 26 young healthy adults using four different NB CE-chirps centered at 500, 1000, 2000, and 4000 Hz. The neck torsion method was applied for electrode placement. To have the acute recording, visual feedback of sternocleidomastoid muscle contraction was provided, and electromyography (EMG) scaling was done. Results: cVEMPs were present for 100% across all frequencies except at 4000 Hz. Amplitudes between each pair of frequencies were significantly different for EMG scaled and unscaled conditions. Frequency tuning was observed at 500 Hz regardless of scaling done. Positive peak 1 of cVEMP (P1) latencies showed no differences between frequencies while both negative peak 1 of cVEMP and the complex of positive peak 1 and negative peak 1 of cVEMP (P1N1) interpeak latency values decreased with increasing frequency. Interaural amplitude asymmetry ratio showed no difference between scaled and unscaled amplitudes. Intraclass correlation revealed a range of test–retest reliability across frequencies. EMG unscaled amplitude were having relatively lower test–retest reliability consistently across frequencies Conclusions: Differences in amplitudes between frequencies with a maximum at 500 Hz can be attributed to the low frequency centered saccular response. No differences in P1 were observed. Yet, N1 latency and P1N1 interpeak latency difference gradually shortened with the decrement in the stimulus duration as the stimulation frequency increased. The lower reliability of EMG unscaled amplitude across frequencies supports the need to use EMG scaling to avoid confounding variables related to muscle contraction.

Publisher

American Speech Language Hearing Association

Subject

Speech and Hearing

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3