Changes in Acoustic Absorbance Pre– and Post–Cochlear Implantation

Author:

Racca Jordan M.12ORCID,Jones Laura L.3,Dwyer Robert T.14,Ferguson Mary1,Sunderhaus Linsey1,Hood Linda J.1,Gifford René H.1ORCID

Affiliation:

1. Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, Nashville, TN

2. Department of Radiology, Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN

3. Department of Audiology, MedStar Georgetown University Hospital, Washington, DC

4. Advanced Bionics LLC, Valencia, CA

Abstract

Purpose: Until recently, there has been little investigation on the effects of cochlear implantation on the transmission of acoustic stimuli through the middle-ear system. Recent studies have shown that cochlear implantation decreases low-frequency acoustic absorbance, consistent with a stiffer middle-ear system postsurgery. The objectives of this study are (a) to investigate the time course of changes in acoustic absorbance post–cochlear implantation in the implanted ear and (b) to compare changes in acoustic absorbance between implanted and nonimplanted ears over time. Method: Seventeen adult cochlear implant (CI) recipients within 6 months of device activation participated in this study. Wideband acoustic absorbance was measured in both ears at one to six different time points from pre-implantation up to 6-month postactivation. Analyses examined (a) changes in acoustic absorbance as compared to pre-implantation and (b) differences in acoustic absorbance between implanted and nonimplanted ears over time. Results: Acoustic absorbance in the implanted ear decreased postsurgery for frequencies lower than 1.5 kHz and persisted through at least 6-month postactivation. We also observed that the spectral range of decreased acoustic absorbance in the implanted ear decreased with longer time postsurgery. Differences in acoustic absorbance between implanted and nonimplanted ears occurred over a broad spectral range at the activation time point and persisted through at least 3-month postactivation, though for a narrower spectral range at the later time point. Conclusions: Cochlear implantation increased middle-ear stiffness as indicated by decreased acoustic absorbance of low-frequency acoustic power. The findings of this study are consistent with those of previous studies and may have important implications toward understanding spatial hearing and programming of acoustic components for CI-combined electric and binaural acoustic stimulation patients.

Publisher

American Speech Language Hearing Association

Subject

Speech and Hearing

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3