Masked Speech Recognition as a Function of Masker Location for Cochlear Implant Users With Single-Sided Deafness

Author:

Anderson Kelly M.12,Buss Emily1ORCID,Rooth Meredith A.1ORCID,Richter Margaret E.1,Overton Andrea B.3,Brown Kevin D.1ORCID,Dillon Margaret T.12ORCID

Affiliation:

1. Department of Otolaryngology/Head & Neck Surgery, University of North Carolina at Chapel Hill

2. Division of Speech and Hearing Sciences, Department of Allied Health Sciences, University of North Carolina at Chapel Hill

3. Department of Audiology, UNC Health, Chapel Hill, NC

Abstract

Purpose: Cochlear implant (CI) recipients with normal or near normal hearing (NH) in the contralateral ear, referred to as single-sided deafness (SSD), experience significantly better speech recognition in noise with their CI than without it, although reported outcomes vary. One possible explanation for differences in outcomes across studies could be differences in the spatial configurations used to assess performance. This study compared speech recognition for different spatial configurations of the target and masker, with test materials used clinically. Method: Sixteen CI users with SSD completed tasks of masked speech recognition presented in five spatial configurations. The target speech was presented from the front speaker (0° azimuth). The masker was located either 90° or 45° toward the CI-ear or NH-ear or colocated with the target. Materials were the AzBio sentences in a 10-talker masker and the Bamford-Kowal-Bench Speech-in-Noise test (BKB-SIN; four-talker masker). Spatial release from masking (SRM) was computed as the benefit associated with spatial separation relative to the colocated condition. Results: Performance was significantly better when the masker was separated toward the CI-ear as compared to colocated. No benefit was observed for spatial separations toward the NH-ear. The magnitude of SRM for spatial separations toward the CI-ear was similar for 45° and 90° when tested with the AzBio sentences, but a larger benefit was observed for 90° as compared to 45° for the BKB-SIN. Conclusions: Masked speech recognition in CI users with SSD varies as a function of the spatial configuration of the target and masker. Results supported an expansion of the clinical test battery at the study site to assess binaural hearing abilities for CI candidates and recipients with SSD. The revised test battery presents the target from the front speaker and the masker colocated with the target, 90° toward the CI-ear, or 90° toward the NH-ear.

Publisher

American Speech Language Hearing Association

Subject

Speech and Hearing

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3