The Accuracy of Smartphone Sound Level Meter Applications With and Without Calibration

Author:

Serpanos Yula C.12,Renne Brittany12,Schoepflin Janet R.12,Davis Diane12

Affiliation:

1. Department of Communication Sciences and Disorders, Adelphi University, Garden City, NY

2. Long Island Doctor of Audiology Consortium, Garden City, NY

Abstract

Purpose The purpose of this study is to determine the accuracy of smartphone sound level meter applications (SLMAs) with calibration features across stimulus levels and for ambient room noise measures in the clinical setting. Method The accuracy of 3 iOS-based smartphone SLMAs (SLMA1: Analyzer [Version 2.7.2, DSP Mobile], SLMA2: Sound Level Meter Pro [Version 2.2, Mint Muse LLC], and SLMA3: SPL Meter [Version 9.3, Andrew Smith, Studio Six Digital]), using a single smartphone device (iPhone 6S Model A1688, iOS 9.3.4, Apple), was evaluated with and without calibration using a 1000-Hz narrowband noise (NBN) and white noise (WN) stimuli over a range of sound levels (20–100 dB) and in ambient noise measures of 8 speech and hearing room environments. A simultaneous and corresponding SLMA and Type 1 sound level meter (SLM) measure per condition were documented with a photo image; each condition was replicated 5 times. Mean SLMA and SLM measures were compared. SLMA measures were considered accurate if within ± 2 dB of the SLM. Results Measures of NBN and WN signals using these SLMAs were accurate at levels above 40–50 dB when calibrated. NBN and WN signals using some SLMAs were significantly ( p < .05) more accurate with calibration at levels > 40 to 50 dB. SLMA measures with or without calibration adjustment were inaccurate and overestimated room ambient noise levels < 50 dB. Conclusions These findings suggest that some SLMAs are accurate for measuring NBN and WN stimuli within the range of 50–100 dB in sound-treated environments when calibrated. However, outcomes indicated that some SLMAs, even with calibration, overestimated low ambient noise levels and may not accurately verify quiet room environments < 50 dB for clinical services. These results should not be generalized for all smartphone types, and continued research on SLMAs using next-generation smartphone devices is warranted.

Publisher

American Speech Language Hearing Association

Subject

Speech and Hearing,Linguistics and Language,Developmental and Educational Psychology,Otorhinolaryngology

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3