A Systematic Review of Pharyngeal High-Resolution Manometry Normative Data

Author:

Walters Rameen K.1ORCID,Gudipudi Rachana1,Gordis Tamar1,Davidson Kate2,Nguyen Shaun A.1,O'Rourke Ashli K.1

Affiliation:

1. Department of Otolaryngology–Head & Neck Surgery, Medical University of South Carolina, Charleston

2. Department of Speech-Language Pathology, Medical University of South Carolina, Charleston

Abstract

Purpose: The utilization of high-resolution pharyngeal manometry (HRPM) in the evaluation of pharyngeal dysphagia has been increasing; however, standardization of its use has lagged behind. Without standardization using normative values, it is difficult for clinicians to adopt this emerging technology into meaningful use. Our goal is to map and compare the published normative values for common HRPM metrics in order to help establish consensus reference values. Method: A systematic review was conducted on prospective and retrospective studies that included HRPM metrics, defined by an international working group consensus, in healthy adult populations. Data on the following variables were extracted when available: contractile integrals of the pharynx (PhCI), velopharynx, mesopharynx, and hypopharynx, as well as the upper esophageal sphincter (UES) integrated relaxation pressure (IRP), relaxation time (RT), maximum admittance, and hypopharyngeal intrabolus pressure. Results: Thirty studies were included. Significant variation existed in the technique and equipment used to perform procedures between the different studies. Lower PhCIs and UES IRPs were seen in younger compared to older individuals. Higher UES RTs were found in individuals in the upright position compared to the supine position and in those using larger boluses sizes or smaller catheters. Conclusions: Due to the wide variety of protocols, catheter configurations, manufacturers, and software used in the existing literature, it is difficult to formulate consensus on HPRM normative values using pooled data. Prospective studies adhering to standardized HRPM protocols for specific catheter configurations and manufacturers with larger cohorts of normal individuals are necessary to establish proper reference values for HRPM metrics. Supplemental Material: https://doi.org/10.23641/asha.24843753

Publisher

American Speech Language Hearing Association

Subject

Speech and Hearing,Linguistics and Language,Developmental and Educational Psychology,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3