Tissue-Point Motion Tracking in the Tongue From Cine MRI and Tagged MRI

Author:

Woo Jonghye1,Stone Maureen1,Suo Yuanming2,Murano Emi Z.3,Prince Jerry L.2

Affiliation:

1. University of Maryland School of Dentistry, Baltimore, MD

2. Johns Hopkins University, Baltimore, MD

3. Johns Hopkins Hospital, Baltimore, MD

Abstract

Purpose Accurate tissue motion tracking within the tongue can help professionals diagnose and treat vocal tract–related disorders, evaluate speech quality before and after surgery, and conduct various scientific studies. The authors compared tissue tracking results from 4 widely used deformable registration (DR) methods applied to cine magnetic resonance imaging (MRI) with harmonic phase (HARP)–based tracking applied to tagged MRI. Method Ten subjects repeated the phrase “a geese” multiple times while sagittal images of the head were collected at 26 Hz, first in a tagged MRI data set and then in a cine MRI data set. HARP tracked the motion of 8 specified tissue points in the tagged data set. Four DR methods including diffeomorphic demons and free-form deformations based on cubic B-spline with 3 different similarity measures were used to track the same 8 points in the cine MRI data set. Individual points were tracked and length changes of several muscles were calculated using the DR- and HARP-based tracking methods. Results The results showed that the DR tracking errors were nonsystematic and varied in direction, amount, and timing across speakers and within speakers. Comparison of HARP and DR tracking with manual tracking showed better tracking results for HARP except at the tongue surface, where mistracking caused greater errors in HARP than DR. Conclusions Tissue point tracking using DR tracking methods contains nonsystematic tracking errors within and across subjects, making it less successful than tagged MRI tracking within the tongue. However, HARP sometimes mistracks points at the tongue surface of tagged MRI because of its limited bandpass filter and tag pattern fading, so that DR has better success measuring surface tissue points on cine MRI than HARP does. Therefore, a hybrid method is being explored.

Publisher

American Speech Language Hearing Association

Subject

Speech and Hearing,Linguistics and Language,Language and Linguistics

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3