Affiliation:
1. California State University, Long Beach
Abstract
The purpose of this study was to investigate how accurately pure-tone (250–6000 Hz) loudness discomfort levels (LDLs) predict speech (CID Test W-22) LDLs. One ear was tested in each of 50 elderly subjects with mild-to-moderate sensorineural hearing loss. The results revealed poor-to-fair correlations (r = 0.00 to 0.42) and large standard errors of estimate ( 9.5 dB). Thus, it was concluded that pure-tone LDLs are not accurate predictors of the speech LDL, and, if the clinician wants to ascertain the upper intensity for listening to speech, this measurement must be made directly.
Publisher
American Speech Language Hearing Association
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献