Results of the Estimation of Biosimilarity of RinLiz® (LLC «GEROPHARM», Russia) and Humalog® (Lilly France, France) Using the Method of the Hyperinsulinemic Eulygemic Clamp on Healthy Voluntary

Author:

Mayorov A. Yu.1,Fedotov I. A.2,Drai R. V.3,Avdeeva O. I.3,Makarenko I. E.3ORCID

Affiliation:

1. Endocrinology Research Centre

2. LLC «BioEk»; LLC «Eco-Safety Research Center»

3. LLC «GEROPHARM»

Abstract

Introduction. Insulin is the most effective hypoglycemic agent currently used in the clinical practice. Compared with recombinant human insulin, insulin lispro have a blood glucose profile that is much closer to physiological. The clinical trials program of insulin bioassays includes pharmacology studies: pharmacokinetics (PK), pharmacodynamics (PD), and a clinical safety study.Aim. To compare PK and PD of RinLiz® U100, solution for intravenous and subcutaneous administration (LLC «GEROFARM», Russia) and Humalog® U100, solution for intravenous and subcutaneous administration (Lilly France, France) in hyperinsulinemic euglycemic clamp.Materials and methods. This was randomized double-blind, two-arm crossover study in 28 healthy volunteers (NCT03604575). The studied preparations were injected before the clamp with a dose of 0.3 U/kg once subcutaneously in the area of subcutaneous fat in the anterior abdominal wall. During the study, regular blood sampling was performed; the amount of insulin lispro was determined by ELISA in the samples. The results of the determination were used to calculate the PK parameters and construct the curves «concentration – time». Based on the measurement of glycemia, the glucose infusion rate was adjusted. These data were used to calculate the PD parameters. The comparability of the studied drugs was considered proven if 90 % confidence intervals (CI) for the ratio of geometric mean PK parameters Cins. max and AUCins. 0-8 and 95 % CI for the ratio of geometric mean PD parameters GIRmax and AUCGIR0-8,5 were in the range of 80–125 %. Statistical data processing and presentation of the results was carried out using software packages R 3.4.2.Results and discussion. In the course of CI comparative PK and PD of RinLiz® and Humalog®, it was revealed that they have comparable PK and PD profiles. The CI for the logarithmically converted ratios of the values of the PK parameters was Cins. max 85.99–96.85 % and AUCins. 0-8 90.58–97.28 %, the PD of the parameters were 95.64–118.94 for GIRmax and 96.5–121.36 for AUCGIR0-8.5, all the CIs correspond to the set the boundaries of 80–125 % to establish comparability between RinLiz® and the original drug.Conclusion. The results demonstrated the high degree of similarity of RinLiz® U100 and Humalog® U100 in terms of PK, PD profiles and safety.

Publisher

Center of Pharmaceutical Analytics Ltd

Subject

Drug Discovery,Pharmaceutical Science

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3