A Double-blind Randomized Comparative Phase I Study to Assess Biosimilarity and Immunogenicity of "Trastuzumab" (LLC "Mabscale", Russia) and Herceptin® (F. Hoffmann-La Roche Ltd., Switzerland) in Healthy Volunteers

Author:

Kolganova M. A.1ORCID,Beketov E. E.2ORCID,Pisarev V. V.3ORCID,Ivanov A. V.3ORCID,Vasiliev S. V.4ORCID,Shokhin I. E.5ORCID

Affiliation:

1. LLC "Mabscale"; LLC "Center for Pharmaceutical Analytics"

2. LLC "Mabscale"; A. Tsyb MRRC – branch of NMRRC of the Ministry of Health of the Russian Federation

3. LLC "Scientific and Production Center Probiotech"

4. LLC "ELC Clinic"

5. LLC "Center for Pharmaceutical Analytics"

Abstract

Introduction. Trastuzumab is the first drug based on the monoclonal antibodies’ technology targeted to the neu oncogene expression product discovered in the middle 80-s – human epidermal growth receptor, HER2. After being approved trastuzumab had become the drug of choice for combine therapy of metastatic breast cancer (BC). This therapy had also allowed to improve patients’ 5-year survival rate dramatically, almost up to 90 % in some cases. Despite the fact that more than 10 biosimilars of trastuzumab are now in the pipeline around the world, including Russia, the development and registration of trastuzumab biosimilars still remain relevant.Aim. Aim of the study was to conduct the analytical part of the double-blind randomized comparative clinical trial for trastuzumab pharmacokinetics and safety assessment in healthy volunteers with subsequent biosimilarity evaluation of "Trastuzumab" (LLC "Mabscale", Russia) and Herceptin® (F. Hoffmann-La Roche Ltd., Switzerland).Materials and methods. 92 healthy volunteers, who fulfilled the inclusion/exclusion criteria, were enrolled to the study. Trastuzumab quantitation and anti-trastuzumab antibodies detection was performed using ELISA method with photometric detection. To support the clinical trial two different independent bioanalytical methods were validated.Results and discussion. Trastuzumab quantitation method in human blood serum was validated for selectivity, calibration curve and regression model, sensitivity (LLOQ), accuracy and precision, MRD, dilution linearity and stability. The method for anti-trastuzumab antibodies detection, that was previously described by the authors, was validated for cut-point, selectivity, sensitivity, prozone effect, drug tolerance, precision and stability (short-term and long-term). The validated methods were successfully applied to the study samples assay to perform the analytical part of the comparative study for trastuzumab pharmacokinetics and immunogenicity assessment. The obtained drug concentrations were used for PK-parameters and confidence interval calculations to estimate the biosimilarity of test and reference drug.Conclusion. The study results showed that test and reference drug are biosimilar, and moreover immunogenicity assessment showed no anti-trastuzumab antibodies in any samples of healthy volunteers.

Publisher

Center of Pharmaceutical Analytics Ltd

Subject

Drug Discovery,Pharmaceutical Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3