Development and Validation of an HPLC-MS/MS Method for Quantification of Apixaban in Human Plasma

Author:

Filonova U. D.1ORCID,Karnakova P. K.2ORCID,Karnakova K. K.2ORCID,Popova M. O.2ORCID,Popova A. A.2ORCID,Archakova O. A.2ORCID,Komarov T. N.3ORCID,Shohin I. E.1ORCID

Affiliation:

1. LLC "Center of Pharmaceutical Analytics" (LLC "CPHA"); National Research Nuclear University MEPhI (Moscow Engineering Physics Institute)

2. LLC "Center of Pharmaceutical Analytics" (LLC "CPHA")

3. LLC "Center of Pharmaceutical Analytics" (LLC "CPHA"); Peoples' Friendship University of Russia named after Patrice Lumumba (RUDN University)

Abstract

Introduction. Apixaban is an anticoagulant used in a number of thromboembolic diseases with an improved benefit-to-risk ratio, according to multiple clinical studies. Due to the prescription of apixaban as antithrombotic therapy in patients with COVID-19, an increase in its use has been observed. Thus, due to the widespread use of apixaban and the need to conduct pharmacokinetic and bioequivalence studies of the drug, it is important to develop and validate a simple and sensitive method for the quantitative determination of apixaban in human blood plasma.Aim. The aim of the study is to develop and validate a method for the determination of apixaban in human blood plasma using high-performance liquid chromatography with tandem mass selective detection (HPLC-MS/MS) for the subsequent bioanalytical study.Materials and methods. The determination of apixaban in human plasma was carried out by HPLC-MS/MS with rivaroxaban as an internal standard. The method of protein precipitation with acetonitrile was used as sample preparation. Mobile phase: 0.1 % solution of formic acid in water (eluent A); 0.1 % solution of formic acid in acetonitrile (eluent B). The total run time was 3.00 min. Column: Shim-pack Velox Biphenyl; 2.7 µm; 50 × 2.1 mm. Ionization source: electrospray with positive ionization mode. MRM transitions: 460.15 → 443.10 m/z (apixaban); 436.05 → 144.95 m/z (rivaroxaban).Results and discussion. The developed method was validated in accordance with the EAEU requirements for the following parameters: selectivity, calibration curve, accuracy and precision, lower limit of quantitation, suitability of standard samples, matrix effect, recovery, stability, carry-over, dilution effects. The parameters met the acceptance criteria.Conclusion. The confirmed analytical range of the developed and validated method was 1.00–300.00 ng/mL in blood plasma. The method for determining apixaban in blood plasma is simple and sensitive. This method was tested during the analytical part of the bioanalytical study and can be used to conduct other pharmacokinetic studies of apixaban drugs.

Publisher

Center of Pharmaceutical Analytics Ltd

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3