Bioequivalence assessment of topical clobetasol propionate products using visual and chromametric assessment of skin blanching

Author:

Au Wai Ling,Skinner Michael,Kanfer Isadore

Abstract

ABSTRACT - PURPOSE: The assessment of the degree of skin blanching following the application of a formulation containing a topical corticosteroid has been established as a surrogate method for the determination of bioequivalence of such topical preparations. Whereas initially the procedure involved visual assessment of the blanching response, an instrumental procedure using a chromameter was subsequently recommended as the method of choice in such evaluations. In this study, both visual and chromametric assessments have been carried out on two topical creams containing clobetasol propionate (0.05%) and the results from both methods are compared and discussed. METHODS: Human subjects (volunteers) were subjected to screening using a cream containing 0.05% clobetasol propionate, in order to identify appropriate subjects for inclusion in the study. Subsequently the study was implemented according to the FDA guidance using both visual and chromameter assessment techniques. Blanching responses were assessed visually by three trained, independent observers and instrumentally using a Chromameter. An ED50 of 36 min was used as the dose duration based upon data previously obtained from a pilot study using the same topical corticosteroid reference product. A visual rating scale of 0-4 and the a-scale readings from the chromameter were used. RESULTS: The visual and chromameter blanching profiles showed similar blanching responses and corresponded well with each other. The 90% confidence interval for the visual and chromameter data were calculated using Lock's method and when only the data obtained from 23 subjects who were identified as "detectors" (according to the FDA guidance) were used, the products fell within the bioequivalence acceptance range of 80-125% using the visual assessment method (99.3-111.6%) whereas the data using a chromameter (86.5-129.3%) were just outside the acceptance limits. However, when all subjects (n=34) were included in the calculations, both the visual (97.9-109.2) and chromameter (90.2-120.7) data fell within the acceptance range for the declaration of bioequivalence.CONCLUSIONS: Whereas visual data indicated bioequivalence using either data from "detectors" or data from all subjects, the chromameter data from "detectors" only indicated bioinequivalence but inclusion of all subject data fell within the acceptance range to be declared bioequivalent.

Publisher

University of Alberta Libraries

Subject

Pharmaceutical Science,Pharmacology

Cited by 12 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3