Parameters affecting substance P measurement in heart, lung, and skin

Author:

Erin Nuray12,Clawson Gary A.1

Affiliation:

1. Penn State University, Hershey Medical Center, Hershey, PA, USA

2. Akdeniz University, Antalya, Turkey

Abstract

Substance P (SP), a neuropeptide that is widely distributed both peripherally and centrally, mediates several pathophysiological processes. Among current assays for SP, enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (RIA) have been most widely used. Several previous studies, mostly performed with nerve extracts or organ perfusates, determined that acidity of the extraction buffer as well as the number extractions performed constitute factors influencing accurate measurements. We used an ELISA protocol in this study to analyze methodological aspects of SP measurement in extracts from heart, skin, and lung. The extraction procedure had two steps, an acid extraction followed by a column extraction. We could effectively measure SP with extract from as little as 10 mg of tissue. For each tissue examined, different variables influenced the SP measured. For all tissues, the weight of tissue extracted was critical; the more tissue extracted, the lower the sensitivity of the assay. This problem could be overcome in skin by omitting the column extraction. When mechanical loses were considered (e.g., loss during extraction and SP retained by the column after elution), column extraction improved SP measurements only with lung tissue. The amount of SP remaining in the sample after the first extraction also varied among tissues. The first acid extraction effectively isolated 80% of total SP from skin. In contrast, the first extraction with lung tissue recovered only 58%. Because both acid and heat effectively release SP from nerve endings, this could reflect the presence of non-neuronal SP, especially in lung. High-dose capsaicin treatment, which depletes SP in nerve endings, caused 42% loss of SP in skin independent of amount of tissue extracted. Our results suggest that a second acid extraction of tissue should be performed and that column extraction is clearly detrimental with skin samples.

Publisher

Future Science Ltd

Subject

General Biochemistry, Genetics and Molecular Biology,Biotechnology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3