Long-Range and Highly Sensitive DNase I Footprinting by an Automated Infrared DNA Sequencer

Author:

Machida Masayuki1,Kamio Hiroshi1,Sorensen David1

Affiliation:

1. National Institute of Bioscience and Human-Technology

Abstract

We have shown that an automated DNA sequencer is applicable to fluorescencebased detection of fragments in DNase I footprinting. We demonstrated the potential of long-range and highly sensitive DNase I footprinting taking advantage of an infrared- fluorescence automated DNA sequencer. Footprints of human transcription factor Sp1 were reproducibly detected ranging approximately between 100 and 750 bp on both strands of an 895-bp DNA fragment in a single electrophoresis run. We developed techniques in data collection and subsequent image processing for highly sensitive detection. Less than 0.1 footprinting unit (fpu; approximately 4.5 ng) of Sp1 was detected using 3.1 fmol of a 512-bp DNA fragment. This is greater than 10-fold increase in sensitivity over what has previously been reported by visible dye fluorescence DNA sequencers. This method will be very important in systematic analysis of transcription regulatory regions and in largescale analysis of the transcription process.

Publisher

Future Science Ltd

Subject

General Biochemistry, Genetics and Molecular Biology,Biotechnology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com