Author:
Rao T. N,Prasanthi Y.,Botsa Parvatamma,Kumara G.,Rao K. A.,
Abstract
A simple and inexpensive method was developed using high performance liquid chromatography with PDA detection for determination of granisetron hydrochloride and related impurities (2-methyl-N- [(1R,3r,5S)-9-methyl-9-azabicyclo[3.3.1]non-3-yl]-2H-indazole-3-carboxamide, 1-Methyl-N-[(1R,3r,5S)- 9-methyl-9-azabicyclo[3.3.1]non-3-yl]-1H-indazole-3-carboxamide hydrochloride, N-[(1R,3r,5S)-9- azabicyclo[3.3.1]non-3-yl]-1-methyl-1H-indazole-3-carboxamide and 1-methyl-1H-indazole-3-carboxylic acid. The chromatographic separations were achieved on (250×4.6 mm), 5.0 μm make: Waters, Symmetry Shield C8 column employing acetonitrile: 2% V/V H3PO4 in MilliQ water + 0.1% V/V hexylamine in water, 800:200 V/V (pH adjusted to 7.5 using triethylamine) mobile phase with isocratic programme. A flow rate of 1.5 mL/min was chosen. Four impurities were eluted within 20 minutes. The column temperature was maintained at 40°C and a detector wavelength of 300 nm was employed. The method was successfully validated by establishing system suitability, specificity, linearity, accuracy, limit of detection and limit of quantification.