Author:
Gandhi Santosh V., ,Sawarkar Shivani R.,Damle Mrinalini C.
Abstract
Ceritinib is an anti-cancer of drug used in treatment of non-small cell lung cancer. A high-performance thin layer chromatography (HPTLC) method has been developed for ceritinib, which is stability indicating and simple, precise, and discriminating. The stationary phase used was aluminum-backed silica gel60 F254 plates with chloroform: methanol: glacial acetic acid as the mobile phase in the ratio of 8.5:1.5:0.5 (V/V/V). The retention factor was found to be 0.34 ± 0.02. The densitometric scanning was performed at 277 nm. The linear range for analysis was 100–600 ng band-1, which gave good linear relationship with regression coefficient of 0.998. Method accuracy was proved by the recovery studies. The detection limit and quantification limit were 7.38 and 10.03 ng band-1, respectively. Stress degradation studies like hydrolysis under different pH conditions, photolytic, thermal, and oxidative degradation were carried out as per ICH Q1A (R2) and Q1B guidelines. The method established was found to be robust, and thus it can be used as a stability-indicating method.
Publisher
Indian Drug Manufacturers' Association (IDMA)
Subject
Drug Discovery,Pharmaceutical Science,Pharmacology
Reference10 articles.
1. 1. https://en.wikipedia.org/wiki/Ceritinib accessed on 10 June 2021
2. 2. Antolčić M., Runje M. and Galić N.: A simple and sensitive LC-MS/MS method for determination and quantification of potential genotoxic impurities in the ceritinib active pharmaceutical ingredient, Anal. Methods, 2020, 12(25), 3290-3295.
3. 3. Du P., Guan Y., An Z., Li P. and Liu L.: A selective and robust UPLC-MS/MS method for the simultaneous quantitative determination of anlotinib, ceritinib and ibrutinib in rat plasma and its application to a pharmacokinetic study, Analyst, 2019, 144(18), 5462-5471.
4. 4. Sakuntala M.S., Carey M.W. and Rao A.L.: Development and validation of HPLC method for determination of ceritinib in rabbit plasma using PDA detector, Int. J. Pharm. Sci. Res., 2018, 9(7), 2897-2904.
5. 5. Kumar C.N, Prathyusha V. and Kannappan N.: A novel validated stability indicating RP-HPLC method development for the estimation of ceritinib in it's bulk and finished dosage form as per ICH guidelines, Der Pharm. Lett., 2014, 6(5), 339-351.