1. Department of Medical Physics, Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, Department of Medical Physics and Radiation Protection, University Hospital, Department of Biophysics, Faculty of Medicine, Jagiellonian University Medical College, Center for Theranostics, Jagiellonian University, Krakow, Poland

2. Department of Medical Physics, Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University, Krakow, Poland

3. Endocrinology Department, Jagiellonian University Medical College, Krakow, Poland

Abstract

Background: The aim of the study is to optimise the value of B parameter (β), which is used in the Q.Clear reconstruction in the imaging of neuroendocrine tumours. The study is divided into two parts: analysis of phantom data aiming at selection of the appropriate β for small changes, and then assessment of its impact on the quality of patients' images. The literature data on the optimal β value are inconclusive. Furthermore, the suggested values are not the result of the semi-quantitative assessment of Standard Uptake Volume (SUV) or the proper verification based on, for example, phantom studies using the known activity. Results: The obtained results show that β increase raises the image uniformity in the Q.Clear reconstruction algorithm. Also, referring to the scientific reports, one can see that the signal to noise ratio in the image increases. The effect of the β change on the SUV mean and Contrast Recovery Coefficient (CRC) value is greatest for the smallest objects. The decrease of this parameter is also much higher with lower values of activity (a lower counts statistic in the PET system). Conclusions: An increase of β has an adverse effect on the quality of a semi-quantitative assessment of SUV – as the parameter increases, the SUV and CRC values decrease. In the visual assessment, a satisfactory image quality is present with β = 450. Based on the analysis of SUV and CRC, an appropriate range of β values was selected as 350–450. At the selected range, a retrospective analysis of the clinical images of neuroendocrine tumours will be performed in the future and the impact of the change on the semi- -quantitative analysis of pathological changes will be verified.

Publisher

Index Copernicus

Subject

Health Informatics,Biochemistry, Genetics and Molecular Biology (miscellaneous),Medicine (miscellaneous),General Computer Science

Reference15 articles.

1. Tong S, Alessio A, Kinahan P. Image reconstruction for PET/CTscanners: past achievements and future challenges. Imaging Med.2010;2:529-45.

2. Vennart J, Bird N, Buscombe J, Cheow HK, Nowosinska E, Heard S.Optimization of PET/CT image quality using the GE ‘Sharp IR’point-spread function reconstruction algorithm. Nuc Med Commun.2017;38:471-9.

3. Ross S., Q.Clear, GE Healthcare.

4. Otani T, Hosono M, Kanagaki M. Clinical evaluation and optimizationof Q.Clear; a new PET reconstruction algorithm. J Nuc Med.2017;58(Suppl 1):575.

5. Reddy R, Hainer J, Sticka W, Park M-A. Evaluation of different reconstructionalgorithms in contrast recovery for noncentrally locatedsmall lesions. J. Nucl. Med. 2018;59(Suppl 1):1775.