Evaluation of Modular J-PET sensitivity

Author:

Tayefi Ardebili Faranak1ORCID,Niedźwiecki Szymon1ORCID,Moskal Paweł2ORCID

Affiliation:

1. M. Smoluchowski Institute of Physics, Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University; Total-Body Jagiellonian-PET Laboratory, Jagiellonian University; Theranostics Center, Jagiellonian University, Krakow, Poland

2. M. Smoluchowski Institute of Physics, Faculty of Physics, Astronomy and Applied Computer Science, Jagiellonian University; Total-Body Jagiellonian-PET Laboratory, Jagiellonian University; Theranostics Center, Jagiellonian University, Kraków, Poland

Abstract

The Modular J-PET represents the latest advancement in the Jagiellonian-PET series, utilizing extended plastic scintillator strips. This prototype's modular design enables cost-effective imaging of multi-photon annihilation and positronium, allowing for easy assembly, portability, and versatility. Additionally, its lightweight construction facilitates static bed examinations with a mobile detection system that can be positioned conveniently alongside the patient, negating the requirement for spacious clinical settings. Comprising 24 modules arranged in regular 24-sided polygons circumscribing a 73.9 cm diameter circle, each module integrates 13 scintillator strips, measuring 50 cm in length and 6 mm × 24 mm in cross-section. Scintillation light is captured at both ends through analog Silicon Photomultipliers (SiPMs). This research presents Sensitivity of the Modular J-PET tomograph, adhering to the NEMA_NU 2-2018 standards. Sensitivity measurement was performed with <sup>68</sup>Ge line source inside the 5 sleeves aluminium phantom placed at center of the detector`s field-of-view (FOV) and 10 cm offset from the center of detector. Analyzing the gathered data involved employing the specialized J-PET Framework software, developed within the C++ architecture. To validate the experimental findings, comparisons were made with GATE simulations, wherein the source and phantom were emulated in the same configuration as employed in the actual experiment. The system sensitivity of the Modular J-PET was assessed to be 1.03 0.02 cps/kBq in the center of the detector`s FOV with the peak sensitivity of 2.1 cps/kBq. However, the simulations indicate that at the center of the detector's FOV, the Modular J-PET achieves a system sensitivity of 1.32 0.03 cps/kBq, with a peak sensitivity of 2.9 cps/kBq.

Publisher

Index Copernicus

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3