Optimization of the WLS design for positron emission mammography and Total-Body J-PET systems

Author:

Georgadze Anzori1ORCID,Shivani Shivani2,Ardebili Keyvan Tayefi3ORCID,Moskal Paweł4ORCID

Affiliation:

1. Institute for Nuclear Research of the NAS of Ukraine, Kyiv, Ukraine, Institute of Physics, University of Tartu, Tartu, Estonia

2. Faculty of Physics, Astronomy, and Applied Computer Science, Jagiellonian University, Krakow, Poland

3. Doctoral School of Exact and Natural Science, Jagiellonian University, Faculty of Physics, Astronomy, and Applied Computer Science, Jagiellonian University, Total-Body Jagiellonian-PET Laboratory, Jagiellonian University, Center for Theranostics, Jagiellonian University, Krakow, Poland

4. Faculty of Physics, Astronomy, and Applied Computer Science, Jagiellonian University, Total-Body Jagiellonian-PET Laboratory, Jagiellonian University, Center for Theranostics, Jagiellonian University, Krakow, Poland

Abstract

Total-body positron emission tomography (PET) instruments are medical imaging devices that detect and visualize metabolic activity in the entire body. The PET scanner has a ring-shaped detector that surrounds the patient and detects the gamma rays emitted by the tracer as it decays. Usually these detectors are made up of scintillation crystals coupled to photodetectors that convert the light produced by the scintillation crystal into electrical signals. Jagiellonian Positron Emission Mammograph (J-PEM) is the first J-PET prototype module based on a novel idea with a plastic scintillator and wavelength shifter (WLS). At the same time, it is a prototype module for the TotalBody J-PET system. J-PEM can be an effective system for the detection and diagnosis of breast cancer in its early stage by improving sensitivity. This can be achieved using the superior timing properties of plastic scintillators combined with the WLS sheets readout. In this paper we present an application of the Geant4 program for simulating optical photon transport in the J-PEM module. We aim to study light transport within scintillator bars and WLS sheets to optimize gamma-ray hit position resolution. We simulated a pencil beam of 511 keV photons impinging the scintillator bar at different locations. For each condition we calculated the value of the pulse height centroid and the spread of the photon distribution. Some free parameters of the simulation, like reflectivity and the effective attenuation length in the sheet, were determined from a comparison to experimental data. Finally, we estimated the influence of the application of WLS layer in the Total-Body J-PET on the scatter fraction. To optimize the performance of the J-PEM module we compared geometry WLS strips 50 and 83. It was found that spatial resolution was 2.7 mm and 3.5 mm FWHM for 50 and 83 WLS strips, respectively. Despite the better granularity, the 83-strip WLS geometry exhibited poorer resolution due to fewer photons being transmitted to the strip, resulting in large fluctuations of signal.

Publisher

Index Copernicus

Subject

Health Informatics,Biochemistry, Genetics and Molecular Biology (miscellaneous),Medicine (miscellaneous),General Computer Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3