Abstract
Abstract
This work describes the design, fabrication, modeling, and testing of monolithic micromachined parylene-based electroactive membranes (µPEMs) with embedded microfluidic channels. The design and modeling employed analytical plate theory to determine the optimal membrane dimensions and structural shapes for various microsystem designs. The µPEMs were fabricated using a combination of surface and bulk micromachining techniques incorporating Parylene C as a biocompatible polymeric structural material combined with patterned electrodes for actuation. Experimental actuation of the electroactive membranes demonstrated reliability with minimal voltage shifts, and theoretical pull-in voltages closely matching experimental results. Different structural parameters of the µPEMs were also tested, such as varying the overall membrane thickness/structural rigidity and actuation chamber depth. Dynamic actuation of the membrane, including, the deflection and system response to various actuation frequencies, was observed and quantified via optical coherence tomography techniques. Microfluidic architectures were monolithically integrated with the membrane actuator and successfully perfused, with no signs of leakage. This compact microsystem has potential applications in microfluidics and Lab/System-On-a-Chip devices, for use in micromixers, particle manipulators, and applying strain to adherent cells cultured on top of the membrane.
Subject
Electrical and Electronic Engineering,Mechanical Engineering,Mechanics of Materials,Electronic, Optical and Magnetic Materials
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献