Abstract
Abstract
Direct current tests performed in the past on the conductor samples of the toroidal field (TF) ITER coils revealed degradation of current sharing temperature, T
cs. The degradation progresses with repetitive electromagnetic loading, and also with thermal cycles between 4.5 K and room temperature. This feature was observed on short samples in SULTAN test facility (EPFL-SPC, Switzerland) as well as in TF Insert Coil tests in CSMC test facility (Naka, Japan). We present three independent observations suggesting that initiation of sample quench followed by a fast current discharge, which normally complements every I
c and T
cs test in both SULTAN and CSMC, enhances the T
cs degradation rate. The exact mechanism of this contribution to the degradation remains unidentified.
Subject
Materials Chemistry,Electrical and Electronic Engineering,Metals and Alloys,Condensed Matter Physics,Ceramics and Composites