Abstract
Abstract
Design innovations to manage the electric field enhancements and successful use of cryogenic epoxy EP37 as electrical insulation for high temperature superconducting (HTS) cables for electric aircraft applications are reported. Detailed finite element analysis (FEA) of the electric field distribution shows that the highest electric field is at the interface of the ground and electrical insulation layers. The FEA led to the design, fabrication, and experimental characterization of four model cables with stress cones and a direct bond of the ground and insulation layers. Enhanced partial discharge inception voltage (PDIV) was achieved in the model cables by minimizing the electric field enhancements at the ground layer interface. Using a helium gas mixture with 4 mol% H2, with higher intrinsic dielectric strength than pure helium, further enhanced the PDIV. The results warrant further studies on long HTS cables with EP37 as electrical insulation with a direct bond between the insulation and ground layers.
Funder
Office of Naval Research
NASA - University Leadership Initiative