Abstract
Abstract
Flux penetration and AC loss are among the key problems in the application of high-temperature superconductors (HTSs). Through simulation, the value and distribution of AC loss in HTS equipment can be evaluated and optimized in the design stage, so as to ensure the reliability and stability of the equipment. At present, there are many algorithms for AC loss calculation that can be simplified to a two-dimensional model, but for the case of three-dimensional structure such as cable in a spiral structure, there are still some problems such as difficult meshing, difficult convergence, and low efficiency. In this paper, an upgrade of the two-dimensional J model to a three-dimensional J model is proposed, permitting effective calculation of the flux penetration and AC loss in the CORC cable. The reliability of the method is verified by comparing the calculated results with the analytic model and with experimental results. At present, this method can efficiently calculate a 3D CORC model with a total of 15 superconducting tapes in five layers. Also discussed is the feasibility of upgrading to calculate larger models.
Funder
Strategic Priority Research Program of the Chinese Academy of Sciences
National Natural Science Foundation of China
Subject
Materials Chemistry,Electrical and Electronic Engineering,Metals and Alloys,Condensed Matter Physics,Ceramics and Composites
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献