Fluctuations in the collected charge in integrating photoconductive detectors under small and large signals: the variance problem

Author:

Ramaswami Kieran OORCID,Curry Richard JORCID,Hinder IanORCID,Johanson Robert EORCID,Kasap Safa OORCID

Abstract

Abstract Charge collection efficiency (CE) η 0 under small signal conditions, corresponding to a uniform field in the detector medium, has been widely used in evaluating the performance of photoconductive detectors. The present paper answers the question, ‘What is the variance of the collected charge in an integrating detector as a function of photoinjection level and what are the errors if we continue to use the small signal equations?’ The variance σ 0 2 in η 0 under small signals has been theoretically derived in the literature and has been a key factor in the detective quantum efficiency modeling of integrating detectors based on various semiconductors. σ 0 2 is a noise source and can degrade the detector performance under incomplete charge collection. The statistical variance σ 0 2 in the CE η 0, under small signals and the variance σ r 2 in the CE ηr under an arbitrary injection level r (injected charge divided by charge on the electrodes) have been studied using the Monte Carlo simulation model developed in this work to evaluate the difference between σ r 2 and σ 0 2 from small to large signals. Initial injection of electron and hole pairs and their subsequent transport and trapping in the presence of an electric field, which is calculated from the Poisson equation, is used to calculate the photocurrent. Each injected carrier is tracked as it moves in the semiconductor until it is either trapped or reaches the collection electrode. Trapped carriers do not contribute to the photocurrent but continue to contribute to the field through the Poisson equation. The instantaneous photocurrent i ph(t) is calculated from the drift of the free carriers through the Shockley–Ramo theorem. i ph(t) is integrated over the duration of the photocurrent to calculate the total collected charge and hence the CE ηr . The variance σ r 2 in ηr is found from multiple simulations of ηr . The ηr and σ r 2 have been generated over varying charge injection ratios r, the electron and hole ranges μτ, mean photoinjection depths δ and drift mobility ratios b. At full injection, the deviation Δ σ r 2 of the CE variance σ r 2 from the uniform field case σ 0 2 ( i . e . Δ σ r 2 = σ r 2 σ 0 2 ) may be as much as 40% larger or 20% lower than the small signal model prediction. This study provides the extent of errors involved in the variance of the CE in non-uniform fields and quantifies the increase in errors that can occur in high injection cases. In practice, typical injection ratios are less than 0.2, which means that the magnitude of percentage error Δ σ r 2 / σ 0 2 is less than 5%.

Funder

University of Saskatchewan

University of Manchester Photon Science Institute

Natural Sciences and Engineering Research Council of Canada

University of Manchester

Ian Cottam

Publisher

IOP Publishing

Subject

Surfaces, Coatings and Films,Acoustics and Ultrasonics,Condensed Matter Physics,Electronic, Optical and Magnetic Materials

Reference29 articles.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3