Abstract
Abstract
Reinforced Aerated Concrete panel building systems are preferred as wall elements in residences and industrial facilities due to their advantages. The signal issue encountered in industrial facilities is caused by fires that occur. Fire resistance of sustainably reinforced aerated concrete panels was investigated. The wall G3/05 class reinforced panel model to be used for the test was preferred. The panel wall has been subjected to a 120-minute fire resistance test. In this process, 1050 C° temperature was measured on the surface exposed to flames, while the wall temperature was read 50 C° on the other surface, and the heat temperature increased to 70 C° only at the panel joints. The data obtained from showed that the reinforced aerated concrete panels maintain their integrity under fire and resistant to high temperatures. These data that reinforced aerated concrete systems should be preferred, in buildings with human population and high fire risk.
Reference33 articles.
1. Study of lightweight concrete behaviour;Bhavana;Int. Jour. of Civil Eng. and Technology (IJCIET),2017
2. Structure of autoclaved porous concrete SIBIT(YTONG);Yurjev;Key Eng Mat,2002
3. Fire resistant buildings with high energy performance;Uğurlu,2015
4. Physical and mechanical characterization of Fiber-Reinforced Aerated Concrete (FRAC);Bonakdar;Cem. Concr Comp,2013